We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Variable Area Flow Meter.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Variable Area Flow Meter Product List and Ranking from 4 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

Variable Area Flow Meter Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

  1. null/null
  2. ティ・アイ・シィ計測器工業 Osaka//Machine elements and parts
  3. 大阪フローメーター工業 Osaka//Industrial Machinery 本社
  4. 4 カワキ計測工業 Hyogo//Testing, Analysis and Measurement
  5. 5 null/null

Variable Area Flow Meter Product ranking

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

  1. Area-type flow meter "NK Series"
  2. Area-type flow meter "Purge Meter LH/EK/A·C·D"
  3. Area-type flow meter "SPT type (vertical simple type)" ティ・アイ・シィ計測器工業
  4. 4 Area-type flow meter "ST model (vertical multipurpose type)" ティ・アイ・シィ計測器工業
  5. 5 Area type flow meter "KS type (vertical type)" ティ・アイ・シィ計測器工業

Variable Area Flow Meter Product List

1~15 item / All 24 items

Displayed results

Area flow meter

The flow area determined by the position of the float inside the tapered pipe has a constant relationship with the flow rate passing through.

A measuring tube with an upward slope (commonly referred to as a tapered tube) contains a float that can move freely up and down, and is assembled with an appropriate support. This is known as a flow meter. When a fluid (liquid, gas, or vapor) flows from below to above, the float is pushed upward due to the force created by the pressure difference that arises before and after it. As the float moves upward, the flow area between the float and the tapered tube increases. As a result, the velocity of the fluid passing through that area decreases, leading to a reduction in the pressure difference, and the float comes to rest at a position where the forces due to its effective weight and the pressure difference are balanced. Since the flow area determined by the position of the float inside the tapered tube and the flow rate passing through it are in a constant relationship, it is possible to measure the flow rate by detecting that position. 【Density of Gases (Excerpt)】 < Name: Density kg/m3 (ntp) / Specific Gravity > ■ Nitrous Oxide: 1.978 / 1.530 ■ Acetylene: 1.171 / 0.906 ■ Argon: 1.784 / 1.380 ■ Ammonia: 0.772 / 0.597 ■ Carbon Monoxide: 1.250 / 0.967 *For more details, please refer to the PDF document or feel free to contact us.

  • Flow Meter

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "ST model (vertical multipurpose type)"

Vertical multipurpose area flow meter consisting of inflow and outflow pipes and a tapered pipe.

This model is a representative type of area flow meter and is a general-purpose instrument with high accuracy. Additionally, due to its shape, it is possible to apply various linings to the liquid contact parts of the inlet and outlet pipes. 【Specifications (excerpt)】 ■ Applications: For measuring transparent fluids and gases (Capable of measuring strong acidic, alkaline liquids, organic solvents, etc.) ■ Manufacturing diameter: 1/4″ to 12″ ■ Model numbers: ST-8 to ST-300 ■ Pressure resistance: Maximum 10 kg/cm² to 30 kg/cm² (static pressure) *For more details, please download the PDF or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area type flow meter "KS type (vertical type)"

Standard flange specification JIS 5kg/m2. A beautifully designed area-type flow meter.

The "KS type (vertical type)" is a flow meter made entirely of acrylic resin for the body and flange section. It has an attractive appearance and is particularly suitable for measuring the flow of pure water and drinking water. The pressure resistance is up to 10 kg/cm² (static pressure). 【Specifications (excerpt)】 ■ Application: For measuring transparent fluids such as drinking water and pure water ■ Manufacturing diameter: 1/2″ to 3″ ■ Model numbers: KS-15 to KS-80 ■ Pressure resistance: Up to 10 kg/cm² (static pressure) ■ Maximum usable temperature: 60℃ *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "SPR model (vertical multipurpose type)"

A representative model of area-type flow meters, a high-precision general-purpose instrument!

The "SPR type (Vertical Multi-Purpose Type)" is a general-purpose instrument consisting of inlet and outlet pipes and a tapered pipe. It is a representative model of area flow meters and offers high precision. Additionally, due to its shape, this device allows for the use of various materials in the liquid contact sections of the inlet and outlet pipes. 【Specifications (excerpt)】 ■ Application: For measuring transparent fluids and gases (Capable of measuring strong acidic, alkaline liquids, organic solvents, etc.) ■ Manufacturing diameter: 1/4″ to 2″ ■ Model numbers: SPR-10 to SPR-50 ■ Pressure resistance: Maximum 10 kg f/cm2G *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "UL type / ULM type"

Side flow, opaque fluid, slurry-containing fluid measurement type. Instruments with built-in magnets are also available.

The "UL type and ULM type" are area-type flow meters designed for use in reverse L-shaped piping installations. This model, like the "ST type," can be equipped with various linings in the wetted parts. The "ULM type" features a built-in magnet and is designed with a sealed structure to prevent liquid leakage from the scale indication section. Therefore, it is suitable for measuring opaque fluids and fluids containing slurries. 【Specifications (excerpt)】 ■ Applications: Measurement of transparent and opaque fluids, gases (Capable of measuring strong acidic, alkaline liquids, organic solvents, etc.) ■ Manufacturing diameter: 3/4″ to 12″ ■ Model numbers: UL-20 to UL-300, ULM-20 to ULM-300 ■ Pressure resistance: Maximum 10 kg/cm² to 50 kg/cm² (static pressure) *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "RLM(diameter)-HF(flange standard) for high temperature"

The maximum operating temperature is 300°C! Area flow meter suitable for horizontal flow and horizontal piping.

This model is an area-type flow meter based on the "RLM type" designed for measuring opaque fluids. It is designed to withstand a maximum pressure of 50 kg/cm²G (static pressure) and can measure superheated saturated water and superheated steam. It is made for use in horizontal flow and horizontal piping. 【Specifications (excerpt)】 ■ Applications: Measurement of transparent and opaque fluids and gases (capable of measuring alkaline, strongly acidic, and organic solvents, etc.) ■ Manufacturing diameter: 1/2″ to 12″ ■ Model number: RLM-15-HF-(flange standard) to RLM-300-HF-(flange standard) ■ Pressure resistance: Maximum 50 kg/cm²G (static pressure) *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "SPA type"

A flow meter designed for measuring chemical quantities, with a focus on material quality!

The "SPA type" is a robust and easy-to-disassemble flow meter that has been miniaturized. Among vertical multi-purpose flow meters, it is designed with a particular emphasis on material properties. The main body is made of acrylic resin, and the threaded parts are made of polyvinyl chloride, making it suitable for measuring various chemicals. 【Specifications (excerpt)】 ■ Applications: For measuring caustic soda solutions and other alkaline liquids, as well as hydrochloric acid solutions and other acidic liquids. ■ Model number: SPA-10 to 20 ■ Manufacturing diameter: 3/8" to 3/4" ■ Pressure resistance: Maximum 10 kg/cm² (static pressure) ■ Maximum operating temperature range: 0 to 60°C *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "INF series"

For small flow rates! Area-type flow meter that can also handle high temperature and high pressure fluids.

The "INF Series" is a small flow area flowmeter specifically designed for horizontal piping. While maintaining the customization capabilities of the SF model, it contributes to reducing piping costs. Please feel free to contact us if you have any inquiries. 【Features】 ■ INF-M Type - Reduces piping costs as it is designed for horizontal piping - High precision, capable of measuring small flow rates - Can measure various fluids - Compatible with high-temperature and high-pressure fluids ■ INF-MA Type, INF-MAA Type - Large contact capacity, usable with high-voltage power sources in overseas locations and paper mills *For more details, please download the PDF or contact us.

  • Flow Meter

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "RHTS TYPE Sanitary Type"

For measuring food, beverages, pharmaceuticals, etc.! A simple structure area flow meter.

The "RHTS TYPE Sanitary Type" is an area-type flow meter with a simple structure that allows for easy disassembly, cleaning, and installation/removal. It has proven to be highly effective for measuring food, beverages, pharmaceuticals, and more. The connection parts are available in both IDF standard rule type and screw type. A protective cover can also be installed upon request. 【Features】 ■ Simple structure ■ Easy disassembly and cleaning ■ Easy installation and removal ■ Effective for food, beverages, pharmaceuticals, etc. *For more details, please refer to the catalog or feel free to contact us.

  • Other flow meters

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "RPVII TYPE Panel Type"

A flow meter designed for high flow rates!

The "RPVII TYPE Panel Type" is an area flow meter designed for high flow rates compared to RPV. With a needle valve, it allows for adjustments in measurement control, making it suitable for measurement control of various equipment and devices. 【Features】 ■ Designed for high flow rates ■ Adjustable measurement control ■ Suitable for measurement control of various equipment and devices *For more details, please refer to the catalog or feel free to contact us.

  • Other flow meters

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "RL TYPE Stand Type"

It is an area-type flow meter that is active in experimental research.

The "RL TYPE Stand Type" is an area flow meter widely used for experimental research purposes. The main body comes with a stand, allowing for easy mobility. 【Features】 ■ Widely used for experimental research ■ Equipped with a stand for easy movement *For more details, please refer to the catalog or feel free to contact us.

  • Flow Meter

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration